Fit Flap Position Sensor

| | Comments (0) | TrackBacks (0)
I stopped by the hobby shop tonight and picked up some small 4-40 threaded rod and some threaded clevis ends to connect the flap arm to the Ray Allen position sensor that will feed the flap position to the VP-X.  I stole the dimensions from Mike Bullock's site and they worked perfectly.



I fabricated a small clip that bolts to the adel clamp to connect the clevis to the flap rod.  I used a piece of 0.063" angle with one leg mostly cut off.  This wraps around side of the adel clamp flange and will prevent it from rotating.



Here's the other end.  I didn't tighten the nut fully since it interferes with the nut on the clevis.



I turned the screw around on the clevis and tightened it more fully.  I ended up also having to use one of these tiny lock nuts to provide clearance from the clevis screw.



0 TrackBacks

Listed below are links to blogs that reference this entry: Fit Flap Position Sensor.

TrackBack URL for this entry: http://www.jasonbeaver.com/mt/mt-tb.cgi/537